Radon testing and mitigation basics in Canada: the 200 Bq/m3 guideline, the 91-day test, and what mitigation costs

Health & Safety · 7 min read · Published November 1, 2026

The Canadian answer is one number and one test. Health Canada's action level for radon is 200 Bq/m3. A result only counts for a mitigation decision when it comes from a long-term test: a detector placed in the lowest regularly occupied level of the home for at least three months, the 91-day minimum, ideally during heating season. Everything else in this guide hangs off those two facts: what the test costs, how to read the result against the guideline, how fast to act at each level, and what a mitigation system costs when the number comes back high.

General information only: this guide summarises published Health Canada guidance and Canadian radon resources for general information. It is not medical advice and it does not assess any individual home or any individual's health risk. For health questions, talk to a qualified health professional. For testing and mitigation in a specific home, Health Canada points homeowners to C-NRPP certified professionals.

Radon in Canada: why this is a test-every-home issue

Start with the testing gap. Health Canada guidance notes that more than 90 percent of Canadian homeowners have never tested for radon. A house cannot be sorted into the action bands below from the outside, from its age, or from a neighbour's result, the bands only mean something once a detector has sat in the home through a proper test period.

There is also a second number worth knowing so it does not confuse the reading later. The World Health Organization reference level is 100 Bq/m3, lower than Health Canada's 200 Bq/m3 action level. The Canadian guideline, the Canadian timelines, and the Canadian costs in this guide all key off 200 Bq/m3. Keep the two numbers separate: 100 is the WHO reference level; 200 is the level Health Canada sets action timelines against.

That separation matters because a large share of radon content online is written for another country's guideline, in different units. A result reported in Bq/m3 gets read against one line only here: 200 Bq/m3.

The only test that counts for a decision: 91 days, heating season

Health Canada guidance is specific about duration and season: place a detector in the lowest regularly occupied level for at least three months during the heating season. A mitigation decision still needs at least three months of data, even when the reading comes from an electronic monitor rather than a mailed-in kit. Shorter runs can screen, but they do not settle the question the guideline asks.

Three ways to run the long test appear in the Canadian sources, at three different prices:

Test routeCost in the sourcesDecision-grade?
Long-term DIY kit$30 to $60Yes, when it runs at least three months in heating season
Electronic radon monitor$200 to $350, reusableYes, but only after at least three months of data
C-NRPP certified measurement professionalMuch higher cost than a DIY kitYes, professional placement and reading

The DIY kit is the low-cost entry point: the sources put long-term kits at $30 to $60. Electronic monitors run $200 to $350 and are reusable, which suits a household that expects to retest, but the purchase price buys convenience, not a shortcut, because the three-month data rule applies to monitors exactly as it applies to kits. C-NRPP certified professionals are available at much higher cost than the DIY route.

Spec check before trusting any result. Before a number gets compared with 200 Bq/m3, verify four things about how it was produced: the unit is Bq/m3; the detector ran for at least three months (91 days); the run fell in heating season; and the detector sat in the lowest regularly occupied level. A result that fails any one of those checks is a screening number, not a decision number, and the fix is a proper long-term retest, not a mitigation quote built on a short run.

Placing the detector: lowest lived-in level, done right

The placement rule in Health Canada's guidance has three parts, and each part protects the reading. First, the level: the lowest regularly occupied level of the home, because that is the level the guideline's test describes. Second, the duration: at least three months, left in place for the full run rather than moved between rooms. Third, the season: heating season, the period the guidance names for the test.

Two habits keep the run clean. Write down the start date on the day the detector goes out, so the 91-day count is a record rather than a guess. Then leave the detector where it was placed until the run ends, a detector that spends part of the period on a different level has measured a mix of levels, and the result no longer matches the test the guideline describes.

Reading the result against 200 Bq/m3: the two timelines

Once a decision-grade result exists, the reading is a lookup, not a judgement call. The Canadian sources give three bands:

Long-term resultAction in the Canadian guidance
Below 200 Bq/m3Retest every 5 years or after major renovations
200 to 600 Bq/m3Mitigate within 2 years
Above 600 Bq/m3Mitigate within 1 year

Three worked readings show how the table gets used. A long-term result of 150 Bq/m3 sits below the guideline: no mitigation timeline starts, and the standing instruction is to retest every five years or after major renovations. A result of 350 Bq/m3 lands in the middle band: mitigation is due within two years. A result of 700 Bq/m3 is above 600 Bq/m3, and the timeline tightens to one year. Note what the bands do not contain: there is no band in which a result above the guideline calls for waiting without a deadline.

The five-year retest rule for below-guideline homes has a second trigger worth underlining: major renovations. A home that tested below 200 Bq/m3 and then goes through major renovation work is due a fresh long-term test on the renovation trigger, not only on the calendar.

Mitigation: sub-slab depressurization, costs, and the retest

The method the Canadian sources price is sub-slab depressurization. Its published performance range is an 80 to 99 percent reduction in radon levels, and Health Canada guidance gives the same picture from the other direction: a mitigation system can be installed in less than a day and reduces radon by more than 80 percent in most homes.

Professional mitigation in Canada typically costs $2,000 to $4,500 installed. Put the full path together and the total cost of the decision looks like this:

PathTest costMitigation costAll-in total
DIY kit, result below 200 Bq/m3$30 to $60$0, no timeline starts$30 to $60
DIY kit, then professional mitigation$30 to $60$2,000 to $4,500$2,030 to $4,560
Electronic monitor, then professional mitigation$200 to $350$2,000 to $4,500$2,200 to $4,850

Read the table as a decision aid. The test itself is the cheap part of every path, $30 to $60 by kit. The expensive line only appears when a decision-grade result lands at or above 200 Bq/m3, and the timelines in the previous section say how long a household has to budget for it: two years in the middle band, one year above 600 Bq/m3. A household that tests early in a heating season holds the longest possible planning window the guidance allows.

After mitigation, the standing measurement habit does not change: the below-200 Bq/m3 band carries the retest rule, every five years or after major renovations, and a post-mitigation result is read against the same 200 Bq/m3 line as any other long-term result.

What not to do: short tests, US action levels, and deciding on a screening number

Three errors account for most bad radon decisions, and each one is a misuse of a number rather than a missing product.

Deciding on a short run. A test that ran for less than three months has not produced the data a mitigation decision needs, whatever device recorded it. The sources are explicit that even a reusable electronic monitor does not shorten the requirement: at least three months of data, in heating season, on the lowest regularly occupied level.

Reading a Canadian result against a foreign action level. Results in Canada are reported in Bq/m3 and judged against Health Canada's 200 Bq/m3 guideline, with the WHO's 100 Bq/m3 figure present only as a reference level. Importing another country's action level, stated in different units, on a different basis, scrambles both the band lookup and the timeline that follows from it.

Skipping the test because testing feels optional. With more than 90 percent of Canadian homeowners never having tested, the untested house is the normal case, not the safe case. The kit that settles the question costs $30 to $60 and one heating season of patience. That is the whole entry price to a decision the guideline can actually support.

, Tom Reilly, Home & DIY Writer