Replacing a failed sump pump in Canada: diagnose the failure first, then swap it
10 years is the replacement horizon the Government of Canada puts on a sump pump, and 7 to 10 years is the useful lifespan most guides cite. A pump inside that window that stops working has usually not died all at once. One part failed: the switch that tells it to start, the motor that does the work, the check valve that keeps pumped water from falling back into the pit, or the power feeding it. Each failure has a different fix and a different price, and only one of them requires a new pump. Diagnose first, with a bucket of water and ten minutes, and the replacement decision makes itself.
Job summary
Difficulty is moderate for a like for like swap in a pit that already has a check valve and a union fitting, and low for the switch and valve fixes that often come first. Time runs about an hour for a swap once the diagnosis is done. Tools: a bucket, a flashlight, an adjustable wrench, a PVC cutter or hacksaw, and a towel for the water that will come out of the discharge pipe. The hire a pro line sits at a damaged pit, a discharge line that needs rerouting, or any sign of sewage in the water.
Diagnose before you buy: four symptoms, four fixes
Run the bucket test first. Lift the pit cover, clear any debris touching the float, plug the pump in, and pour a pail of water slowly into the pit until the float rises. The pump should switch on, empty the pit, and switch off on its own. Ontario maintenance guidance suggests testing monthly where possible, and at least in spring and fall, before the thaw and before a big storm. What the test shows sorts the failure:
| What the test shows | Likely failed part | The fix |
|---|---|---|
| Nothing happens, and the float is stuck against the pit wall or the discharge pipe | Float switch, jammed rather than dead | Free the float, clear silt and gravel from the pit, retest |
| Nothing happens, the float moves freely, and the outlet has power | Switch or motor | Replace the pump; a switch failure on an older pump is the common story, and one London, Ontario retailer notes most flooded basements with a pump in the pit trace back to a switch that never fired, not a dead motor |
| The pump hums, or trips the breaker, without moving water | Motor or impeller | Replace the pump; Toronto replacement services list exactly this symptom as a book the swap signal |
| The pump empties the pit, stops, and water flows back in, so it soon restarts | Check valve | Replace the check valve, a small part, before pricing a pump |
| The pump runs constantly, even in dry weather | Stuck switch, failed check valve, or an undersized pump | Work the three causes in that order; constant running alone is not proof the motor is done |
Age settles ties. A pump past 10 years that fails any branch of the table gets replaced rather than repaired, because the remaining parts are the same age as the part that failed. A pump at 4 years with a jammed float gets its Saturday back.
The swap, step by step
- Cut the power. Unplug the pump and switch off its breaker. Success looks like a pit you can reach into safely.
- Disconnect the discharge. Loosen the union or couplings above the check valve and expect the water standing in the pipe to drain back into the pit.
- Lift the old pump out and note its horsepower and discharge size before it goes into a bucket for transport. Most homes run a 1-1/4 inch or 1-1/2 inch discharge.
- Match the replacement to the pit, not the shelf. A 1/3 HP pump, roughly 2,000 to 3,000 gallons per hour, suits most average homes. Step up to 1/2 HP, roughly 3,000 to 4,200 gallons per hour, for a high water table or a history of heavy inflow. In a narrow pit, choose a vertical float switch; a tethered float needs room to swing.
- Set the new pump level on the pit floor, connect the discharge, and fit a new check valve with its flow arrow pointing away from the pump.
- Restore power and run the bucket test again. Success is specific: the float rises, the pump starts, the pit empties, the pump stops, and no water rushes back in. Run it twice.
- Check outside. The discharge should end well away from the foundation. Government of Canada guidance puts it at least 1.5 metres away where possible, and Ontario guidance suggests 10 to 20 feet so the water does not soak straight back in.
The backup decision, made with numbers
Basements flood during storms, and storms are when power fails, which is why the Government of Canada recommends a backup battery or generator operated pump alongside the main one. The swap is the cheapest moment to add one, because the pit is already open and the plumber, if you hired one, is already there. Decide from your own history: a finished basement, a pit that cycles often in spring, or a street with repeated outages argues for the backup. An unfinished basement with a pump that runs twice a year argues for a high water alarm first and the backup later. If you add the backup, put its battery on the calendar: replacement every 3 to 5 years is the standing guidance, and the backup gets the same bucket test as the main pump, run with the main pump unplugged.
What it costs in Canada, DIY versus hired out
| Route | Dated figure | Source |
|---|---|---|
| Basic plastic pump, pump only | About $99 | Household Plumbing, London, Ontario, checked November 25, 2026 |
| Cast iron pump with rod float, pump only | About $263 | Household Plumbing, London, Ontario, checked November 25, 2026 |
| Pump only swap, installed | $360 to $900 | Tornado Plumbing, Toronto 2026 pricing, checked November 25, 2026 |
| Pump plus new check valve, installed | $450 to $1,100 | Tornado Plumbing, Toronto 2026 pricing, checked November 25, 2026 |
| Pump plus battery backup, installed | $1,400 to $3,500 | Tornado Plumbing, Toronto 2026 pricing, checked November 25, 2026 |
The comparison that frames the whole job sits outside the table. Restoring a typical flooded Canadian basement runs $12,000 to $18,000, per ServiceMaster Restore figures cited by the London retailer. Against that, the difference between the $99 pump and the $263 cast iron pump is not the decision. The decision is whether the switch design and the backup match how your pit actually behaves, which the diagnosis above already told you.
Common mistakes, and the hire a pro line
Three mistakes repeat. First, reusing the old check valve to save a few dollars, then listening to the new pump short cycle against the water falling back in. Second, buying horsepower by headline flow without checking the flow at your pit's vertical lift, which is the number that decides whether the pump keeps up. Third, skipping the second bucket test and finding the fault during the next storm instead. Hire a pro when the pit itself is cracked or undersized, when the discharge needs rerouting, when there is any sign of sewage, or when the electrical side needs more than a plug. Everything short of that list is a diagnosis, a like for like swap, and two bucket tests.
— Tom Reilly, Home & DIY Writer