Replacing interior doors on a budget: the slab vs prehung decision
Replacing a houseful of dated interior doors looks like a shopping problem, pick a style, count the openings, order, and it is actually a frame problem. The cheapest door is the one that fits the opening it is bought for, once. A slab door, which is only the door panel, is the affordable route when the existing frame is sound and square, because the frame, trim and paint around it all stay. A prehung door, which arrives already hung in its own new frame, is the affordable route when the frame has failed, because fitting a new slab into a twisted frame is labour spent on a door that will bind, gap and rattle from the day it is hung. Every budget guide states the first half of that sentence, slab costs less, prehung is easier, and stops before the test that decides which half applies to a given opening. This guide starts with the test.
Start with the frame, not the door catalogue
The definitions matter because they decide what is being kept. A slab is simply the door panel itself, without a frame, hinges, or bore holes for the hardware. Retail listings state the same boundary plainly: a product such as a Masonite 30 by 80 inch primed hollow core slab is sold as slab only and does not include frame or hinges. A prehung unit is the opposite package: the door already mounted, on its hinges, into a new three-sided frame, often with the lockset preparation done. Angi's comparison summarises the working difference: prehung doors are more do-it-yourself friendly because the job becomes shimming and securing a frame, while slab doors come in more sizes and avoid installing a new frame at all.
Neither package is cheaper in the abstract. The slab's lower purchase price is real, and so is what it demands in return: replacing a door this way requires customising the new slab to the precise dimensions, hinge locations and hardware placements of the old door and the existing frame, which is a higher degree of carpentry skill than setting a prehung unit. The budget question is therefore not "slab or prehung?" but "what condition is this frame in, and is the skill, yours, or a hired carpenter's, already paid for?"
The frame test: keep it or replace it
Run these checks on every opening before ordering anything. The rule behind them is the one the comparison guides agree on: a slab is only advisable if the existing frame is in good condition, because a damaged frame will continue to deteriorate and cause further problems even with a new slab installed, and if the frame is damaged, or the doorway size is changing, a prehung unit is easier and faster than a slab.
| Check | How | Keep the frame (slab) if | Replace it (prehung) if |
|---|---|---|---|
| Soundness | Press a screwdriver tip into the bottom of each jamb and the hinge jamb; look for rot, splits at hinge screws, and cracked casing joints | The wood is firm everywhere and hinge screws bite and hold | Any jamb is soft, split, or no longer holds hinge screws |
| Plumb | Hold a level against each jamb | Both jambs are plumb, or out by a small, consistent amount the old door already accommodates | A jamb leans enough that the old door's gaps are visibly wedge-shaped |
| Square | Measure the opening's two diagonals and compare them | The diagonals match closely and the head jamb is level | The diagonals differ enough that a rectangular slab would need heavy angled trimming to follow the opening |
| Reveal history | Close the old door and read the gaps around it | Gaps are roughly even and the latch meets the strike cleanly | The door binds in one corner, floats in another, and the latch only catches seasonally |
| Hinge mortises | Inspect the recesses in the jamb edge where the hinge leaves sit | Mortises are crisp, flat and unrepaired | Mortises are chewed, filled, or in mismatched positions from previous doors |
Score each opening separately. In most dated houses the honest result is mixed: most frames pass and take slabs, one or two fail and get prehung units. That mix is the budget, money is saved by not replacing sound frames, and not wasted by slabbing over failed ones. A doorway being resized fails automatically: that is prehung territory by definition, because the frame the slab would have kept no longer exists.
Slab vs prehung compared
| Slab | Prehung | |
|---|---|---|
| What arrives | The door panel only, no frame, no hinges, no bore unless ordered machined | Door hung in a new frame, hinges fitted, often bored for the lockset |
| What must already exist | A frame that passed the test above, with usable hinge mortises and strike position | A rough opening the new unit fits, with room to shim it plumb and square |
| The skilled work | Transferring measurements, mortising for hinges, boring for the lockset, trimming and bevelling to the opening | Setting, shimming and fixing the frame true, then casing both sides |
| What it disturbs | Almost nothing around the opening, trim and surrounding paint stay | The old frame and trim come out; casing, and sometimes wall finish, are redone |
| Best budget case | Several sound frames, standard sizes, and the time to fit carefully | Failed frames, or many doors where one repeatable frame-setting process beats per-door custom fitting |
| Worst budget case | A slab ordered from a single width measurement, or fitted into a frame that failed the test | Replacing a sound frame and its trim to save fitting a slab that would have taken an afternoon |
Take the full measurement packet before ordering a slab
This is the spec verification step, and it is where budget slab swaps are actually won or lost. For a slab replacement, measure the existing slab itself rather than the frame opening, the old door is the template for the opening as it truly is. Record all of the following, for each door, on one sheet:
- Width at three heights, top, middle and bottom of the old slab, plus height at three positions. Old doors and old frames are rarely perfectly parallel, and one number hides it.
- Thickness at the edge. Standard interior slabs are typically 1-3/8 inches thick, and Masonite's interior systems are built as 1-3/8 inch or 1-3/4 inch systems, confirm which one the frame's stop and hinges were made for before ordering.
- Hinge mortise positions. Measure from the top of the door to the top of each hinge mortise, and record the mortise size: usually 3.5 inches by 3.5 inches for a standard interior door, with a corner radius commonly 1/4 inch or 5/8 inch. Masonite's specification matches the pattern: 1-3/8 inch doors are machined for standard weight 3-1/2 inch radius mortise hinges.
- Bore and backset. The knob bore is 2-1/8 inches in diameter; the backset, edge of the door to the centre of the bore, is either 2-3/8 inches or 2-3/4 inches, and Masonite bores to exactly those two options. Record also the distance from the top of the door to the centre of the bore, so the new knob lands where the strike plate already is.
- Handing. Note which side the hinges are on and which way the door swings, room by room, in plain words on the sheet, "hinges left, swings into bedroom" survives ordering better than a left-hand label applied from memory at the store.
- Undercut. Measure the gap under the old door over the finished floor, and more over carpet if flooring is changing, so the replacement clears and still closes over the same floor.
A worked example of why the packet matters: the Home Depot Canada listing for a Masonite Logan slab gives a complete identity for one door, 30 by 80 inches, hollow core, primed, composite, no bore, 27 pounds. "No bore" is the line budget buyers miss. An unbored slab is the right, cheaper product only if the boring will be done on site to the recorded backset; ordered by accident for a frame whose strike sits at the other backset, or expected to arrive ready for a knob, it becomes the second trip and the second door that erase the slab saving.
Spend the core budget room by room
Once the frame decision is made, the second budget lever is core type, and it should be pulled room by room, not house-wide. Hollow core is the budget default: a hollow interior, typically a cardboard or frame lattice inside moulded skins, light to handle and easy to hang. Solid core replaces that void with dense material, and the published sound figures quantify what the money buys: solid core doors typically achieve a Sound Transmission Class rating between 27 and 30, while hollow core doors often fall between 20 and 25. Solid core also resists the dents and punctures that thin hollow skins suffer, and feels substantially heavier in the hand, the Logan example's 27-pound hollow slab is the light end of the range a solid equivalent exceeds.
| Room | Core call | Reason |
|---|---|---|
| Bedroom | Solid core if the budget allows one upgrade tier anywhere | Sleep and privacy are where the STC gap is actually heard, nightly |
| Bathroom | Solid core | Privacy, and a heavier door reads as quality in the smallest room in the project |
| Home office | Solid core | Calls and concentration are a sound problem before they are anything else |
| Living and dining openings | Hollow core | Doors that stand open most of the day gain little from sound mass |
| Closets and storage | Hollow core | The lightest duty in the house; spend nothing extra here |
| Laundry and utility | Either, decide by noise | If machine noise reaches bedrooms, treat it like a bedroom door; otherwise hollow is fine |
Solid wood sits above both as the premium material and is outside a budget project's scope by design; naming it here marks the boundary rather than recommending it. The allocation above usually lands at two or three solid core doors in a whole-house swap, the total premium stays small, and it is spent entirely in the rooms where a visitor, or a teenager, can actually perceive it.
Replace a slab in an existing frame: the procedure
- Complete the frame test and the measurement packet for this opening, in that order. No packet, no order.
- Take the old door down and lay it on the new slab. Align the top and hinge edges, transfer the outline, hinge mortise positions, and bore centre directly from door to door rather than from the written numbers alone, the old slab is the most accurate drawing of the opening that exists.
- Trim to the transferred outline. Take material from the bottom and the latch edge in small passes, respecting any trimming limit the manufacturer states for the product, and bevel the latch edge slightly so the door closes without binding on the jamb.
- Cut the hinge mortises to the recorded size and depth, so each hinge leaf sits flush with the door edge, proud leaves push the door out of line, deep leaves pull it into a bind.
- Bore for the lockset at the recorded height and backset with the 2-1/8 inch bore, then fit the latch through the edge bore and confirm it meets the existing strike position before any paint is opened.
- Hang the door dry. Screw the hinges to the jamb's existing mortises, close the door, and read the reveals: even gaps at head and latch side, clean latch engagement, no spring-back from a binding hinge.
- Take it down and finish it (next section), then rehang, fit the knob set, and adjust the strike once, on the finished door.
What success looks like: the finished door closes with one hand and latches with a soft click, with no shoulder pressure and no lifting by the knob. The gaps around it are even enough to slide a coin of the same denomination around the head and both sides without it jamming or falling through. It stays where it is left at half-open instead of swinging itself shut or open, the sign the hinges, not the frame's lean, are deciding its position. A door that needs a hip to latch has failed the frame test retroactively: the fix is the frame, not a harder push.
Finish all six sides
The step budget projects skip, because the door looks finished once the faces are painted, is the one the manufacturer makes a deadline. Masonite's finishing instructions require that within 7 days of delivery, all six edges of the door, top, bottom and both sides, as well as the faces, and any other unfinished surfaces be sealed with at least two coats of paint, varnish or lacquer, where local code permits, to prevent warping. The bottom edge is the one that matters most and is seen least: bathroom and kitchen humidity reaches it first. Storage before hanging follows the same logic, keep slabs stacked horizontally, fully supported on a level surface, in the recommended 25 to 55 percent relative humidity range, rather than leaned against a wall where a long, thin panel learns a bow it will keep. A primed slab, per its listing, is ready to paint, it is not already finished, and the six-side rule is what "paint it" actually means.
FAQ
Is a slab always cheaper than a prehung door?
The slab itself is the cheaper purchase, and the total job is cheaper only when the existing frame passes the test and the fitting work is yours or already paid for. A slab fitted into a damaged frame, or ordered from incomplete measurements and replaced, costs more than the prehung unit that would have solved the opening in one visit.
Can any existing frame take a new slab?
No. The frame must be sound, plumb enough, square enough, and holding its hinge screws and mortises. A damaged frame keeps deteriorating under a new door; that opening gets a prehung unit, or a repaired frame first.
What measurements are needed before ordering a slab?
Width and height of the old slab at three points each, thickness (typically 1-3/8 inches for interior doors), each hinge mortise's position and size (usually 3.5 by 3.5 inches), the bore diameter (2-1/8 inches), the backset (2-3/8 or 2-3/4 inches), the bore height, the handing and swing, and the undercut over the finished floor.
Where is solid core worth the extra over hollow core?
Where sound and privacy are the point of the door: bedrooms, bathrooms and a home office. Solid core typically rates STC 27 to 30 against hollow core's 20 to 25. Closets, storage and mostly-open living openings gain little, so hollow core keeps the budget there.